== Bearing Reference, Tunnel 1 == | |||
''' #1 - Tail Tracking Roller''' <br> | |||
Roller bearings: RAE 25 RR (2 ea.) <br> | |||
Guide Bearings: RAE 25 NPP (2 ea.) <br> | |||
'''#2 - Idler Carrier Roller''' <br> | |||
RAE 35 NPP FA106 (2ea.) | |||
'''#3 - Tension Roller''' <br> | |||
RAE 25 NPP FA106 (2 ea.) | |||
'''#4 - Tail Scraper Roller''' <br> | |||
RAE 35 NPP FA106 (2 ea.) | |||
'''#5 - Drive/Drum Roller''' <br> | |||
Housing: FC208 (2 ea.) <br> | |||
Bearing: UC208 (2 ea.) | |||
'''#6 - Feed Scraper Roller''' <br> | |||
RAE 35 NPP FA106 (2 ea.) | |||
== Bearing Reference, Tunnel 2 == | |||
== Bearing Reference, Tunnel 3 == | |||
== Line Speed Tach (tunnels 1 & 2): == | |||
'''Items Used:''' | |||
*[[Red Lion Counters / Rate Meters|Red Lion PAXLCR00]] Pax-Lite Dual Counter & Rate Meter | |||
*[[Allen Bradley Sensors|Allen Bradley 872C-D4NP12-E2]] Inductive Proximity Sensor | |||
<br> | |||
'''Red Lion Setup:''' | |||
''Wiring:''<br> | |||
{| class="wikitable" | |||
! style="text-align:center;"| Term# | |||
! Useage | |||
! Wire color | |||
|- | |||
|| 1 || AC || x | |||
|- | |||
|| 2 || AC || x | |||
|- | |||
|| 3 || DC+ || Brown | |||
|- | |||
|| 4 || DC- || Blue | |||
|- | |||
|| 5 || Input A|| Black | |||
|} | |||
''Dip Sw.:'' | |||
{| class="wikitable" | |||
! style="text-align:center;"| SW# | |||
! On/Off | |||
|- | |||
|| 1 || Off | |||
|- | |||
|| 2 || On | |||
|- | |||
|| 3 || Off | |||
|- | |||
|| 4 || Off | |||
|- | |||
|| 5 || Off | |||
|} | |||
''Programming:''<br> | |||
''Menu 1 (Input): "1-INP"'' | |||
{| class="wikitable" | |||
! style="text-align:center;"| Param | |||
! Setting | |||
|- | |||
|| '''INP AB''' (count mode) || CnT ud | |||
|- | |||
|| '''A-DPT''' (decimal position (A)) || 0.0 | |||
|- | |||
|| '''A-ScF''' (counter A scale factor) || 5.0003 | |||
|- | |||
|| '''A-rST''' (counter A reset action) || CnT Lu | |||
|- | |||
|| '''A-dir''' (counter A count direction) || nOr | |||
|- | |||
|| '''Cnt Ld''' (counter A load value) || 48.0 | |||
|- | |||
|| '''b-bat''' (counter B batch count enable) || no | |||
|- | |||
|| '''r P-UP''' (counter reset at power-up) || yes | |||
|- | |||
|| '''USr-INP''' (user input function) || no | |||
|} | |||
''Menu 2 (Rate): "2-rATE"'' | |||
{| class="wikitable" | |||
! style="text-align:center;"| Param | |||
! Setting | |||
|- | |||
|| '''rt-Enb''' (rate enable) || yes | |||
|- | |||
|| '''rt-dPt''' (rate decimal point) || 0.0 | |||
|- | |||
|| '''StyLE''' (rate input scaling style) || Key | |||
|- | |||
|| '''rt-dSP''' (rate scaling display value) || 215.0 (for tunnel 2) | |||
|- | |||
|| '''rt-dSP''' (rate scaling display value) || 195.0 (for tunnel 1) | |||
|- | |||
|| '''rt-INP''' (rate input scaling value) || 63.0 | |||
|- | |||
|| '''LO-Udt''' (rate low update time) || 2.1 | |||
|- | |||
|| '''HI-Udt''' (rate high update time || 2.8 | |||
|} | |||
''Menu 3 (Display & Front Panel): "3-dSP"'' | |||
{| class="wikitable" | |||
! style="text-align:center;"| Param | |||
! Setting | |||
|- | |||
|| '''SEL-En''' (front panel display select enable) || yes | |||
|- | |||
|| '''rSt-En''' (front panel counter reset enable) || yes | |||
|- | |||
|| '''ScroLL''' (desplay scroll enable) || no | |||
|- | |||
|| '''d-LEU''' (display intensity level) || 3 | |||
|- | |||
|| '''Code''' (programming security code) || 0 | |||
|- | |||
|| '''FCS''' (factory service operations) || no | |||
|} | |||
''Menu 4 (Setpoint Output Parameters): "4-SPt"'' | |||
{| class="wikitable" | |||
! style="text-align:center;"| Param | |||
! Setting | |||
|- | |||
|| '''SP SEL''' (setpoint select) || no | |||
|} | |||
Return to --> [[Main Page]]<br> | |||
Return to --> [[List of Machinery]] |
Latest revision as of 14:48, 25 September 2021
Bearing Reference, Tunnel 1
#1 - Tail Tracking Roller
Roller bearings: RAE 25 RR (2 ea.)
Guide Bearings: RAE 25 NPP (2 ea.)
#2 - Idler Carrier Roller
RAE 35 NPP FA106 (2ea.)
#3 - Tension Roller
RAE 25 NPP FA106 (2 ea.)
#4 - Tail Scraper Roller
RAE 35 NPP FA106 (2 ea.)
#5 - Drive/Drum Roller
Housing: FC208 (2 ea.)
Bearing: UC208 (2 ea.)
#6 - Feed Scraper Roller
RAE 35 NPP FA106 (2 ea.)
Bearing Reference, Tunnel 2
Bearing Reference, Tunnel 3
Line Speed Tach (tunnels 1 & 2):
Items Used:
- Red Lion PAXLCR00 Pax-Lite Dual Counter & Rate Meter
- Allen Bradley 872C-D4NP12-E2 Inductive Proximity Sensor
Red Lion Setup:
Wiring:
Term# | Useage | Wire color |
---|---|---|
1 | AC | x |
2 | AC | x |
3 | DC+ | Brown |
4 | DC- | Blue |
5 | Input A | Black |
Dip Sw.:
SW# | On/Off |
---|---|
1 | Off |
2 | On |
3 | Off |
4 | Off |
5 | Off |
Programming:
Menu 1 (Input): "1-INP"
Param | Setting |
---|---|
INP AB (count mode) | CnT ud |
A-DPT (decimal position (A)) | 0.0 |
A-ScF (counter A scale factor) | 5.0003 |
A-rST (counter A reset action) | CnT Lu |
A-dir (counter A count direction) | nOr |
Cnt Ld (counter A load value) | 48.0 |
b-bat (counter B batch count enable) | no |
r P-UP (counter reset at power-up) | yes |
USr-INP (user input function) | no |
Menu 2 (Rate): "2-rATE"
Param | Setting |
---|---|
rt-Enb (rate enable) | yes |
rt-dPt (rate decimal point) | 0.0 |
StyLE (rate input scaling style) | Key |
rt-dSP (rate scaling display value) | 215.0 (for tunnel 2) |
rt-dSP (rate scaling display value) | 195.0 (for tunnel 1) |
rt-INP (rate input scaling value) | 63.0 |
LO-Udt (rate low update time) | 2.1 |
HI-Udt (rate high update time | 2.8 |
Menu 3 (Display & Front Panel): "3-dSP"
Param | Setting |
---|---|
SEL-En (front panel display select enable) | yes |
rSt-En (front panel counter reset enable) | yes |
ScroLL (desplay scroll enable) | no |
d-LEU (display intensity level) | 3 |
Code (programming security code) | 0 |
FCS (factory service operations) | no |
Menu 4 (Setpoint Output Parameters): "4-SPt"
Param | Setting |
---|---|
SP SEL (setpoint select) | no |
Return to --> Main Page