Sollich Tunnels (old)

From BHPedia
Revision as of 14:48, 25 September 2021 by Vintovka (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Bearing Reference, Tunnel 1

#1 - Tail Tracking Roller
Roller bearings: RAE 25 RR (2 ea.)
Guide Bearings: RAE 25 NPP (2 ea.)

#2 - Idler Carrier Roller
RAE 35 NPP FA106 (2ea.)

#3 - Tension Roller
RAE 25 NPP FA106 (2 ea.)

#4 - Tail Scraper Roller
RAE 35 NPP FA106 (2 ea.)

#5 - Drive/Drum Roller
Housing: FC208 (2 ea.)
Bearing: UC208 (2 ea.)

#6 - Feed Scraper Roller
RAE 35 NPP FA106 (2 ea.)

Bearing Reference, Tunnel 2

Bearing Reference, Tunnel 3

Line Speed Tach (tunnels 1 & 2):

Items Used:


Red Lion Setup:

Wiring:

Term# Useage Wire color
1 AC x
2 AC x
3 DC+ Brown
4 DC- Blue
5 Input A Black


Dip Sw.:

SW# On/Off
1 Off
2 On
3 Off
4 Off
5 Off


Programming:
Menu 1 (Input): "1-INP"

Param Setting
INP AB (count mode) CnT ud
A-DPT (decimal position (A)) 0.0
A-ScF (counter A scale factor) 5.0003
A-rST (counter A reset action) CnT Lu
A-dir (counter A count direction) nOr
Cnt Ld (counter A load value) 48.0
b-bat (counter B batch count enable) no
r P-UP (counter reset at power-up) yes
USr-INP (user input function) no


Menu 2 (Rate): "2-rATE"

Param Setting
rt-Enb (rate enable) yes
rt-dPt (rate decimal point) 0.0
StyLE (rate input scaling style) Key
rt-dSP (rate scaling display value) 215.0 (for tunnel 2)
rt-dSP (rate scaling display value) 195.0 (for tunnel 1)
rt-INP (rate input scaling value) 63.0
LO-Udt (rate low update time) 2.1
HI-Udt (rate high update time 2.8


Menu 3 (Display & Front Panel): "3-dSP"

Param Setting
SEL-En (front panel display select enable) yes
rSt-En (front panel counter reset enable) yes
ScroLL (desplay scroll enable) no
d-LEU (display intensity level) 3
Code (programming security code) 0
FCS (factory service operations) no


Menu 4 (Setpoint Output Parameters): "4-SPt"

Param Setting
SP SEL (setpoint select) no


Return to --> Main Page
Return to --> List of Machinery